Skip to content
PVG INTERNATIONALPVG INTERNATIONAL
    • Mobile: +91-9466446612 +91-9728497962
    • E-Mail: info@pvginternationals.com info@narayanienterprises.com
  • Cart

    No products in the cart.

  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog
Add to wishlist
As above but vertical scale. Any other range or size can be made according to buyer’s specification.
Home / Chemistry - General & Chemical Laboratory Apparatus

PM-461 BIMETALLIC THERMOMETER VERTICAL

  • Hand held, accurate and easy to use, battery operated and with built in sensor. Reading displayed on 3 1/2 digit LCD of 12.5 mm height. Range - 50 °C to + 150 °C x 0.1 °C. - 58 °F to 302°F x 1 °F. Accuracy ± 1°C in°C range ± 2 °F in°F range. Power requirements 9 V battery Dimensions 145x46x30 mm lengthxwidthxheight Mass 150 gms (approx.)
  • BIMETALLIC THERMOMETER HORIZONTAL

As above but vertical scale. Any other range or size can be made
according to buyer’s specification.

SKU: PM-461 BIMETALLIC THERMOMETER VERTICAL Category: Chemistry - General & Chemical Laboratory Apparatus
  • Hand held, accurate and easy to use, battery operated and with built in sensor. Reading displayed on 3 1/2 digit LCD of 12.5 mm height. Range - 50 °C to + 150 °C x 0.1 °C. - 58 °F to 302°F x 1 °F. Accuracy ± 1°C in°C range ± 2 °F in°F range. Power requirements 9 V battery Dimensions 145x46x30 mm lengthxwidthxheight Mass 150 gms (approx.)
  • BIMETALLIC THERMOMETER HORIZONTAL
Categories
  • Chemistry - General & Chemical Laboratory Apparatus
  • Laboratory Glassware
    • Distillation Assembly & Rotary Evaporators
    • Laboratory Glassware section -1
    • Interchangeable Laboratory Glassware
    • Organic Chemistry Set
    • Clevenger, Dean & Stark
    • Chromatography Columns & Gas Analysis
    • Clinical Laboratoy Glassware
    • Dairy & Milk Testing
    • Hydrometers
    • Thermometers
    • Quartz Glassware
    • Sintered Glasswae
    • Reaction Vesssel
    • Volumetric Glasswares
  • Anatomical Models
  • Biological Apparatus & Material
  • Microscopes & Accessories
  • Physics & Electronic Laboratory Apparatus
  • Pharmacy Apparatus
  • Earth Sciences
  • Plasticware
  • Uncategories
  • Agriculture Equipment
  • Surgical Instruments & Hospital Equipment
  • Chemicals
  • Material Testing
Recently Viewed
  • NPH-11 FRIABILITY TEST APPARATUS SINGLE Friability testing is a crucial quality control measure in the pharmaceutical industry, assessing the durability of tablets during packaging, handling, and shipping. This test helps ensure that tablets can withstand mechanical shocks without breaking or crumbling, maintaining their integrity and efficacy. The apparatus used for this test is known as a friabilator or friability test apparatus. The principle of a friability tester involves placing tablets in a rotating drum and measuring the weight loss due to chipping or breaking under friction, pressure, or vibration. The majority of the tests use the Friabilator principle. Why Do Pharmaceuticals Perform a Friability Test? Friability testing is performed to check the strength or durability of tablets. Tablets must be strong enough to resist breakage during transportation, coating & blistering process. Friability test is performed for core or uncoated tablets & not performed for coated tablets. Coating polymers give strength & protection to tablets against breaking thats why the Friability Test not performed for Coated Tablets According to the guidelines, tablets should be tested for friability to ensure they do not lose more than a certain percentage of their weight after a specific number of rotations. Speed and Timer Controls: These allow precise setting of the rotation speed and test duration, ensuring consistency across tests. Modern machines may have digital displays for ease of use. Weighing Balance: A highly accurate balance is required to measure the weight of the tablets before and after the test. The Friability Test Apparatus consists of the following key components: Rotating Drum: Typically made of transparent plastic,Acrylic, with a diameter of about 283-291 mm and a depth of approx.40 mm. The drum has a curved baffle that allows tablets to roll and fall within the drum as it rotates. Rotation Speed: The drum rotates at a speed of 25 ± 1 rpm. Timer: Controls the duration of the test, usually set for 4 minutes, equivalent to 100 rotations. Sample Weight: Typically, a sample of 6.5 grams or a specified number of tablets is used. Powder coated mild steel robust Body . Analogue as well as Digital models. Maintenance and Calibration Regular maintenance and calibration of the friability test apparatus are crucial for ensuring accurate and reliable results. This includes: Routine Cleaning: Regularly clean the drum and other components to prevent contamination. Calibration: Periodically calibrate the rotation speed and timer to ensure they are within specified limits. Inspection: Regularly inspect the apparatus for any signs of wear or damage and replace parts as needed. Advantages of Friability Testers Standardized Test Method: Friability testers provide a standardized testing method that is widely accepted and used across the pharmaceutical industry. This ensures that manufacturers can compare their results with industry norms and regulatory requirements. Replicable and Reliable Results: These testers produce consistent and accurate results, allowing manufacturers to evaluate the durability of their tablets and granules under controlled conditions. Fast and Efficient Testing: The Friability Test is a relatively quick process, allowing manufacturers to evaluate the quality of their tablets and granules promptly. This enables manufacturers to identify and address potential issues in their formulation and manufacturing processes. Compliance with Regulatory Guidelines: Friability tests help manufacturers comply with regulatory requirements, ensuring that their products meet the industry’s strict safety and efficacy standards. Early Detection of Issues: The Friability Test can identify potential problems with tablet durability early in the development and manufacturing process. This allows for corrective actions to be taken before large-scale production, minimizing waste and reducing the risk of product failure. Cost-Effective: Friability testers are a relatively affordable investment for manufacturers, providing a cost-effective solution for ensuring the quality and durability of their tablets and granules. Limitations of Friability Testers Limited Scope: Friability testers primarily evaluate the tablet’s ability to withstand mechanical stress during handling and transportation. They do not provide insights into other critical aspects, such as the tablet’s disintegration, dissolution, or drug release properties. Not Suitable for All Tablet Types: Friability tests may not be suitable for all types of tablets, such as coated or enteric-coated tablets. These tablets may require alternative testing methods to properly assess their durability and performance. Limited to Specific Conditions: Friability testers assess the tablet’s durability under controlled conditions, which may not accurately reflect the tablet’s performance in real-world situations. Research and Development Applications Formulation Development: In R&D, friability testers are used not just for quality control but also in the development of new formulations. By testing various formulations, researchers can determine the optimal composition that balances tablet hardness with friability. Material Characterization: Friability tests can also help characterize the mechanical properties of new excipients and binders used in tablet formulations. Conclusion The friability test apparatus is an essential tool in the pharmaceutical / Food /Nutraceutical industry for ensuring tablet durability. By adhering to regulatory standards and maintaining precise machine settings and process parameters, manufacturers can ensure their products meet quality and safety standards. Regular maintenance and calibration further enhance the reliability of the test, contributing to the overall quality assurance process in tablet manufacturing. NPH-11 FRIABILITY TEST APPARATUS SINGLE
  • Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “PM-461 BIMETALLIC THERMOMETER VERTICAL” Cancel reply

Related products

With swivel nozzle, screwed lower end, swan neck same as above but with two angled taps set at 45 , riffled nozzles.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-10 WATER TAP, SWAN NECK

Highly Accurate, Reliable, Portable Instruments for Field and Laboratory Use Salient Features Measures pH, Conductivity, TDS, DO, Salinty, mV & Temperature Turbidity measurement in Deluxe Model Mains cum Battery Operated Available in ABS Plastic Briefcase Technical Specification Model 260 290 Product Digital water & Soil Analysis Kit Deluxe Model Display PH 3 ½ Digit LCD 3 ½ Digit LCD Range 0 to 14 pH 0 to 14 pH Resolution 0.01 pH 0.01 pH Accuracy 0.01± 1Digit 0.01±1 Digit Temp. Comp. 0 to 1000C(/Mannual) 0to1000C(/Mannual) Conductivity (EC) Range 0-200µS 0.20mS 0-2,0-200-200mS Resolution 0.1µS 0.01mS(10µS) Range Selection Mannual ----- Accuracy ±0.5% FS ±1 Digit ±0.5% FS ±1 Digit Cell Constant Adjustable (0.4 to 1.5) Pre-Adjustable Temp. Coefficient. 2% 2% Temp. Comp. Adjustable from table Adjustable from table Ref. Temp. 0-250C 0-250C Temperature Range 0-1000C 0-1000C Resolution 10C 10C Accuracy +/-10C+Digit +/-10C+Digit Sensor Semi Conductor Type Semi Conductor Type   TDS Range 0-200 ppm 0-20 ppt 0-2,0-200-200ppt Range Selection Mannual ------ Resolution 0.01 ppm 0.01ppt Accuracy ±0.5% FS ± 1Digit ±0.5% FS ± 1Digit Temp. Comp. 0.4 to 1.5 on display Pre-Adjustable DO Range 0-20ppm 0-20ppm Resolution 0.1 ppm 0.1 ppt Accuracy 0.5 ppm ± 1 Digit 0.5 ppm ± 1 Digit Temp. Comp. Mannua(50C to 550C) Mannua(50C to 550C) DO Sensor Gold/Silver Amperometric Probe Gold/Silver Amperometric MV (ORP) Range 0 to ± 1999 mV Resolution 1mV Accuracy 1 mV±1 digit Tubidity Range 0-1000 NTU Resolution ----- 1NTU Accuracy +/-3% FS ± 1Digit Sample System 30 mm  Glass Tube Salinity Range 0-50 ppt 0-50 ppt Resolution 0.1 ppt 0.1 ppt Accuracy ±0.5% FS ± 1 Digit 30 mm  Glass Tube Colorimeter Semi Conductor Type 30 mm  Glass Tube Power Supply 1.5V x 6Dry Cells Inbuilt Chargeable Battery Colorimeter or 230V±10¬, 50Hz or 230V ± 10¬, 50Hz
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-895 WATER & SOIL ANALYSIS KIT DIGITAL

Specification: • Upholstered seat • Steel framework • Revolving top • Height adjustable using pneumatic gas spring
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-02 LABORATORY STOOL

High density plastic, with large bore polythene tap, screw on plastic cap, integral moulded handle. Cat. No. Capacity liter 38.01 2 38.02 5 38.03 10 38.04 20 38.05 35 38.06 60
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-38 ASPIRATOR, RECTANGULAR, PLASTIC

WATER TAP, SWAN NECK
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-11 WATER TAP, SWAN NECK

Nontoxic, nonabsorbent, nonflammable, polytetrafloroethylene tape, provides an effective seal on all type of materials such as stainless steel, copper, brass, aluminium, plastic, ceramic etc.; resistant to medium including oils, solvents, water, steam, gases, strong alkalies, acids etc.; can be used over a wide temperature range of -150 C to +250 C; chemically inert so protects fluid against contamination. Excellent electrical insulation property of the tape prevents electric conduction and saves pipes from electric erosion. Requires no drying thus making joints ready for immediate use. Having unlimited shelf life so can be stored easily and indefinitely without loss of properties. Length 10 meter Cat. No. Width x length mm. 30.01 12 30.02 19 30.03 25
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-30 ADHESIVE P.T.F.E. (TEFLON) TAPE

Placeholder
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-348 PROTRACTOR, FULL CIRCLE

Portable electrically heated, with working pressure adjustable from 5 2 lbs to 15 lbs/in , diecast body of high tensile strength aluminium, lid equipped with a spring loaded safety valve of brass adjusted on 15 lbs but can be adjusted to the required pressure by using its 2 chucknut, pressure weight valve set at 17/18 lbs/in work automatically if the other safety valve fails to release the excess 2 steam, with pressure gauze 0-30 lbs/in and closed by six wing nuts having long threaded screw with bakelite knobs, neoprene gasket do not allow any leakage, lid with a metal handle and a bakelite grip, body with a steam release tap system tube having a bakelite knob at right side which is closed before starting and when opened after completion ensures the contents are dry at the end of sterilization process, fitted with a element 2 kW for heating. Complete with 1.5 meter 3 core mains cable for use on 220-240 V, 50 Hz AC. Dimensions of the inner working chamber - Diameter x depth mm. 300 x 300. Spare parts - 1. Gasket for Autoclave 2. Steam release valve with knob. 3. Safety valve. 4. Pressure gauze. 5. Lid handle. 6. Element 2 kW.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-39 AUTOCLAVE

  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog

Address Details

PVG International
# 6 - C, New Ram Nagar, Ambala Cantt - 133 001, Haryana, India.
# P.O. Box-113

Our Visitor

081019

Contact Details

  • info@pvginternationals.com
  • info@narayanienterprises.com
  • +91-9466446612
  • +91-9728497962
  • Phone: +91-171-2651006, 2653272
  • Fax: +91-171-2653259
Copyright 2026 © PVG INTERNATIONAL
  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog
  • Login
    • Mobile: +91-9466446612 +91-9728497962
    • E-Mail: info@pvginternationals.com info@narayanienterprises.com

Login

captcha

Lost your password?

Register

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

captcha