  • Cat. No. Length mm. Cutting edge mm. 837.01 150 20 837.02 200 200 837.03 235 235
  • Forged carbon steel blades. With wooden handle, having brass ferrule. Overall length 250 mm. Cat. No. Size mm. 835.01 6 835.02 12 835.03 19 835.04 25

CHISELS OCTAGONAL
Tampered steel.

Cat. No. Length mm. Cutting edge mm.
836.01 135 9
836.02 150 16
836.03 200 22
836.04 200 25
836.05 250 30
836.06 300 32
SKU: PM-836 CHISELS OCTAGONAL Category: Chemistry - General & Chemical Laboratory Apparatus
  • Cat. No. Length mm. Cutting edge mm. 837.01 150 20 837.02 200 200 837.03 235 235
  • Forged carbon steel blades. With wooden handle, having brass ferrule. Overall length 250 mm. Cat. No. Size mm. 835.01 6 835.02 12 835.03 19 835.04 25
Categories
  • Chemistry - General & Chemical Laboratory Apparatus
  • Laboratory Glassware
    • Distillation Assembly & Rotary Evaporators
    • Laboratory Glassware section -1
    • Interchangeable Laboratory Glassware
    • Organic Chemistry Set
    • Clevenger, Dean & Stark
    • Chromatography Columns & Gas Analysis
    • Clinical Laboratoy Glassware
    • Dairy & Milk Testing
    • Hydrometers
    • Thermometers
    • Quartz Glassware
    • Sintered Glasswae
    • Reaction Vesssel
    • Volumetric Glasswares
  • Anatomical Models
  • Biological Apparatus & Material
  • Microscopes & Accessories
  • Physics & Electronic Laboratory Apparatus
  • Pharmacy Apparatus
  • Earth Sciences
  • Plasticware
  • Uncategories
  • Agriculture Equipment
  • Surgical Instruments & Hospital Equipment
  • Chemicals
  • Material Testing
Recently Viewed
  • Placeholder DeBakey Baimbridge Clamp
  • Placeholder ALGAE
  • 1. Description and Features The NVG-40 measuring cylinder with spout is designed for accurate liquid measurement, specifically catering to experiments and procedures that require precision. These cylinders have a series of distinct features that make them suitable for a wide range of uses: Capacity and Calibration: These measuring cylinders come in various capacities, from as small as 10 ml up to 2 liters or more, depending on user requirements. Each cylinder is calibrated for accuracy, generally according to industry standards, with clear, permanent graduations that allow easy reading. Graduations are marked in both milliliters (ml) and liters (L), allowing for convenient measurement of volumes. Design: Spout: A major distinguishing feature of NVG-40 cylinders is the spout, which allows for controlled and precise pouring of liquids. This helps in preventing spills, reducing waste, and ensuring accurate transfers of liquids. Hexagonal Base: Many NVG-40 measuring cylinders are equipped with a hexagonal base, providing stability and preventing them from easily tipping over during use. This stability is particularly important when working with volatile or hazardous chemicals. Graduation Lines: The graduations are evenly spaced, with clear numerical labels to enable accurate measurements. Typically, the markings are printed in contrasting colors to enhance visibility, even for small amounts of liquid. Material: The NVG-40 measuring cylinders are made from either borosilicate glass or polypropylene (PP) plastic. Borosilicate glass is heat-resistant and chemically inert, making it suitable for working with various reagents, including acidic or basic solutions. Polypropylene plastic is lightweight, resistant to breakage, and compatible with a range of chemicals, but it is less heat-resistant compared to borosilicate glass. Ergonomic Design: The spout and the cylinder are designed to minimize dripping, allowing easy, mess-free pouring. The presence of a thumb rest on some versions ensures that users have a good grip, making them ideal for controlled operations even when one hand is used. Tolerance and Accuracy: The accuracy of these measuring cylinders is defined by their tolerance, which is the allowable range of error in measurements. Generally, the tolerance level meets ISO or ASTM standards, depending on the specific cylinder type. 2. Uses and Applications NVG-40 measuring cylinders with spout are used extensively in both educational and professional laboratories due to their versatility. Below are some of the key applications: Laboratory Use: NVG-40 measuring cylinders are a fundamental part of any laboratory setup, primarily used for measuring liquids with precision. They are widely used in titration processes, where precise volumes of a solution must be added in controlled increments. They can also be employed in preparing solutions by mixing different chemicals, where maintaining an accurate ratio is essential. Industry Use: In the pharmaceutical industry, these measuring cylinders are used for formulation, dilution, and preparation of solutions for further processing. Chemical industries employ measuring cylinders to test the quality of raw materials, create sample mixtures, and for research and development purposes. Educational and Research Institutions: NVG-40 measuring cylinders with spouts are ideal for educational institutions, where students can learn the basics of measurement in chemistry and physics experiments. They are also used in research laboratories for a variety of experiments, ranging from biological assays to materials research. Food and Beverage Industry: Measuring precise volumes is key in the food and beverage industry. These cylinders help in quality control, ensuring that ingredients are added in the correct proportions, and in analyzing products. Environmental and Water Analysis: NVG-40 cylinders are also used in environmental labs, for example, to measure water samples to determine the concentration of contaminants or to perform other tests on wastewater or effluents. 3. Material Properties The choice between borosilicate glass and polypropylene largely depends on the intended use: Borosilicate Glass: Heat Resistance: Borosilicate glass has a very low coefficient of thermal expansion, making it resistant to temperature changes. It can be autoclaved and used for hot liquids. Chemical Compatibility: Borosilicate is resistant to most chemicals, except for hydrofluoric acid. This makes it ideal for work involving reactive chemicals. Transparency: It offers a clear view of the liquid being measured, allowing easy monitoring of the meniscus to read volumes accurately. Polypropylene Plastic (PP): Durability: Polypropylene is highly resistant to breaking and is more durable than glass, which is especially useful for fieldwork or situations where equipment could be dropped. Chemical Resistance: It is resistant to various chemicals, though not suitable for strong acids or bases. Cost: Polypropylene is generally less expensive than borosilicate, making it a cost-effective option for large-volume use or where breakage is a concern. 4. Maintenance and Care To ensure the longevity and accuracy of NVG-40 measuring cylinders, proper care and maintenance are required: Cleaning: Always clean the measuring cylinder after each use. Borosilicate glass cylinders can be washed with laboratory-grade detergents, while polypropylene cylinders should be rinsed with lukewarm water to avoid deformation. It is important to ensure that no chemical residues are left, as they can interfere with future measurements. Handling: Avoid sudden temperature changes with borosilicate glass cylinders, as this can lead to cracking. Ensure the measuring cylinder is placed on a flat, stable surface to prevent tipping over. The hexagonal base design provides additional stability. Storage: Store the measuring cylinders in a dry environment to prevent the buildup of residue or the potential for breakage. Glass cylinders should be stored separately or with padding to avoid contact with other glassware, which could cause damage. 5. Advantages and Limitations Advantages: The spout design allows for easy pouring without spills, making it ideal for applications that require precision. The clear graduation markings provide easy volume measurement, ensuring reproducibility in experiments. Both glass and polypropylene versions offer versatility, catering to the varying needs of different types of laboratories. Limitations: Glass cylinders are prone to breakage and may not be ideal in environments where robust handling is required. Plastic cylinders are more prone to scratching, which can make reading the graduations difficult over time. There is a limited range of volume when compared to other volumetric devices like burettes or pipettes, making it less suitable for extremely precise measurements. NVG-40 MEASURING CYLINDERS WITH SPOUT
  • Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “PM-836 CHISELS OCTAGONAL” Cancel reply

Related products

Placeholder
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-348 PROTRACTOR, FULL CIRCLE

Screwed lower end, with one angle tap.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-09 WATER TAP SWAN NECK

Portable electrically heated, with working pressure adjustable from 5 2 lbs to 15 lbs/in , diecast body of high tensile strength aluminium, lid equipped with a spring loaded safety valve of brass adjusted on 15 lbs but can be adjusted to the required pressure by using its 2 chucknut, pressure weight valve set at 17/18 lbs/in work automatically if the other safety valve fails to release the excess 2 steam, with pressure gauze 0-30 lbs/in and closed by six wing nuts having long threaded screw with bakelite knobs, neoprene gasket do not allow any leakage, lid with a metal handle and a bakelite grip, body with a steam release tap system tube having a bakelite knob at right side which is closed before starting and when opened after completion ensures the contents are dry at the end of sterilization process, fitted with a element 2 kW for heating. Complete with 1.5 meter 3 core mains cable for use on 220-240 V, 50 Hz AC. Dimensions of the inner working chamber - Diameter x depth mm. 300 x 300. Spare parts - 1. Gasket for Autoclave 2. Steam release valve with knob. 3. Safety valve. 4. Pressure gauze. 5. Lid handle. 6. Element 2 kW.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-39 AUTOCLAVE

To hold two burettes, powder coated metal base of size 250x150 mm. thickness 3 mm. with plastic feet, central hole to screw a nickle plated rod of diameter 12 mm. height 60cm.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-642 BURETTE STAND DOUBLE WOODEN

With screwed base for fixing.
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-14 GAS TAP SINGLE, PILLAR MOUNTED

Seamless stainles steel or double walled s.s with safety valve and reinforced bakelite heat resistant handles, safe to operate, with pressure gauze and safety valve level, with a rubber ring gasket fits in the lid so as to make the closure absolutely leak proof. Size, seamless Cat. No. Dia x Depth mm. 40.01 300x300 40.02 350x450 Vertical Double Wall Cat. No. Dia x Depth mm. 40.01 250x400 40.02 300x500 40.03 350x550 40.04 400x600 40.05 450x600 40.06 550x750
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-40 AUTOCLAVE STAINLESS STEEL

GAS TAP, DOUBLE, PILLAR MOUNTED
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-16 GAS TAP, DOUBLE, PILLAR MOUNTED

Borosilicate glass, interchangeable stopper, with stopcock, plain stem. Cat. No. Capacity ml. 417.01 50 417.02 100 417.03 150 417.04 250 417.05 500 417.06 1000
Add to wishlist
Quick View

Chemistry - General & Chemical Laboratory Apparatus

PM-417 FUNNELS DROPPING, CYLINDRICAL

  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog

Address Details

PVG International
# 6 - C, New Ram Nagar, Ambala Cantt - 133 001, Haryana, India.
# P.O. Box-113

Our Visitor

001045

Contact Details

  • info@pvginternationals.com
  • info@narayanienterprises.com
  • +91-9466446612
  • +91-9728497962
  • Phone: +91-171-2651006, 2653272
  • Fax: +91-171-2653259
Copyright 2025 © PVG INTERNATIONAL
  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog
  • Login
    • Mobile: +91-9466446612 +91-9728497962
    • E-Mail: info@pvginternationals.com info@narayanienterprises.com

Login

captcha

Lost your password?

Register

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

captcha