Skip to content
PVG INTERNATIONALPVG INTERNATIONAL
    • Mobile: +91-9466446612 +91-9728497962
    • E-Mail: info@pvginternationals.com info@narayanienterprises.com
  • Cart

    No products in the cart.

  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog
Add to wishlist
Works on 220 V 50 Hz A.C Mains to destroy syringes or needles
Home / Pharmacy Apparatus

NPH-42 NEEDLE DESTROYER

  • Flocculators are used for the determination of the necessary agents required for sedimentation. Used to optimize the coagulant additives and poly-electrolytes for surface and residual water treatment, as well as evaluate the efficiency of an absorbent in toxic agents. The Laboratory flocculators are avialable in either 4 or 6 positions, and have powerful torque to allow stirring and mixing high viscosity substances. Suitable for beakers up to 1000 ml. tall form or 2000 ml. In low Form. Technical Feature Stirrer equipment for 4 or 6 places that accommodates beakers up to 1000 ml. Tall or 2000 ml. Low from. • Stirring speeds from 15 to 200 RPM • Noise Free operation • Adjustable timer up to 999 minutes or continuous operation. • Easy to adjust height over head stir
  • Digital Melting Point Apparatus , constructed using quality components for and Trouble free life. long Used for determining accurate melting points of solids In Pharmaceutical and Drug Industries. With a special arrangement has been made for holding the capillary, which contains the sample, in a uniformly heating media Technical Specifications 0 0 Temperature Range: 2 c Above Room Temperature to 275 c 0 Readability: 1 c Display : 3 Digit LED Display Heating Rate Control : Electronic Stirrer speed Control : Electronic Temperature Probe : PT-100 Oil Capacity : 200 ml. Power Supply : 230 v +-10%, 50 HZ Ac Standard Accessories : Silicon Oil, Magnetic Rotor, A Box of Capillaries, Magnifying Glass, Cylindrical Container, Oil Heater and Temperature Probe.

Works on 220 V 50 Hz A.C Mains to destroy syringes or needles

SKU: NPH-42 NEEDLE DESTROYER Category: Pharmacy Apparatus
  • Flocculators are used for the determination of the necessary agents required for sedimentation. Used to optimize the coagulant additives and poly-electrolytes for surface and residual water treatment, as well as evaluate the efficiency of an absorbent in toxic agents. The Laboratory flocculators are avialable in either 4 or 6 positions, and have powerful torque to allow stirring and mixing high viscosity substances. Suitable for beakers up to 1000 ml. tall form or 2000 ml. In low Form. Technical Feature Stirrer equipment for 4 or 6 places that accommodates beakers up to 1000 ml. Tall or 2000 ml. Low from. • Stirring speeds from 15 to 200 RPM • Noise Free operation • Adjustable timer up to 999 minutes or continuous operation. • Easy to adjust height over head stir
  • Digital Melting Point Apparatus , constructed using quality components for and Trouble free life. long Used for determining accurate melting points of solids In Pharmaceutical and Drug Industries. With a special arrangement has been made for holding the capillary, which contains the sample, in a uniformly heating media Technical Specifications 0 0 Temperature Range: 2 c Above Room Temperature to 275 c 0 Readability: 1 c Display : 3 Digit LED Display Heating Rate Control : Electronic Stirrer speed Control : Electronic Temperature Probe : PT-100 Oil Capacity : 200 ml. Power Supply : 230 v +-10%, 50 HZ Ac Standard Accessories : Silicon Oil, Magnetic Rotor, A Box of Capillaries, Magnifying Glass, Cylindrical Container, Oil Heater and Temperature Probe.
Categories
  • Chemistry - General & Chemical Laboratory Apparatus
  • Laboratory Glassware
    • Distillation Assembly & Rotary Evaporators
    • Laboratory Glassware section -1
    • Interchangeable Laboratory Glassware
    • Organic Chemistry Set
    • Clevenger, Dean & Stark
    • Chromatography Columns & Gas Analysis
    • Clinical Laboratoy Glassware
    • Dairy & Milk Testing
    • Hydrometers
    • Thermometers
    • Quartz Glassware
    • Sintered Glasswae
    • Reaction Vesssel
    • Volumetric Glasswares
  • Anatomical Models
  • Biological Apparatus & Material
  • Microscopes & Accessories
  • Physics & Electronic Laboratory Apparatus
  • Pharmacy Apparatus
  • Earth Sciences
  • Plasticware
  • Uncategories
  • Agriculture Equipment
  • Surgical Instruments & Hospital Equipment
  • Chemicals
  • Material Testing
Recently Viewed
  • YM-116 MODEL OF FEMALE GENITAL ORGANS YM-116 MODEL OF FEMALE GENITAL ORGANS
  • Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “NPH-42 NEEDLE DESTROYER” Cancel reply

Related products

NPH-01 ROTAROD APPARATUS The RotaRod test is one of the oldest tests used for assessing motor coordination and balance in rodents. It provides a quick and simple estimation of neuromuscular coordination. The apparatus consists of a motorized, circular rod turning at a constant or increasing speed. Rota Rod is a measure of the amount of sedation or motor impairment imposed upon an animal undergoing an experimental therapy. Test involves placing the animal on a rotarod, and the time animal can remain on the rod before falling off is measured. The Rota Rod is a Digital motorized apparatus consist of a Horizontal rod which can rotates at a controlled speed.Rod is divided into multiple lanes. Speed of the Rod is adjusted using a motor control unit. Speed can be increased gradually or can be maintained at same speed. When animal falls from the Rod time is taken. Mild Steel construction with powder coated paint finish and steel rod of 25 mm diameter. Instrument has a Long trouble free life Each compartment is with time interval counter. Available in two compartment, three compartment Four and Five compartment models.
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-01 ROTAROD APPARATUS

NPH-06 DISINTEGRATOR Working : Four beaters revolving at high speed inside the machine pulverize material fed into it. The powder thus produced instantly passes through the screens in the lower part of the machine. This free escape of the ground material results in extremely rapid grinding with a fine and cool product. Laboratory Size, for Pharcy, industries, Electrical Motor Driven. Heavy Duty Powder coated mild steel construction. Size reduction in Disintegrator is done by Impacy. Works with four steel hammers. Voltage Required is 220 v 50 Hz A.C mails.
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-06 DISINTEGRATOR MOTOR DRIVEN

The pole climbing apparatus is a laboratory instrument used in pharmacology to study the effects of drugs on cognitive function and antipsychotic activity. It is also used to study how animals learn and retain conditioned responses Used in Pharma Industries, Pharmacy Colleges, Pharmacology Departments. Apparatus consist of Outer chamber made of thick plywood sheet with an observation window Inner animal chamber is made of clear acrylic sheet bottom of which is provided with chrome plated brass bars. A shock for controlled duration of 200V AC 50Hz single phase -0.2ma is built-in and is controlled by built-in 11 position solid state timer upto 30 seconds.\   Output for connection to kymograph or recorder has been brought out as terminal.   An animal dropping removal tray has been provided for keeping the equipment clean.   HOW IT WORKS Animals are trained to jump on a pole to avoid an electrical shock The apparatus can provide audio or light stimuli The apparatus can provide an electrical shock of a controlled duration The apparatus can record the animal's response What it's used for Antipsychotic drugs: The apparatus is used to determine how well antipsychotic drugs work  Cognitive function: The apparatus is used to study how animals respond to conditioned stimuli during learning  Stable baseline behavior: The apparatus is used to induce a stable baseline behavior in animals 
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-18 POLE CLIMBING APPARATUS

NPH-11 FRIABILITY TEST APPARATUS SINGLE Friability testing is a crucial quality control measure in the pharmaceutical industry, assessing the durability of tablets during packaging, handling, and shipping. This test helps ensure that tablets can withstand mechanical shocks without breaking or crumbling, maintaining their integrity and efficacy. The apparatus used for this test is known as a friabilator or friability test apparatus. The principle of a friability tester involves placing tablets in a rotating drum and measuring the weight loss due to chipping or breaking under friction, pressure, or vibration. The majority of the tests use the Friabilator principle. Why Do Pharmaceuticals Perform a Friability Test? Friability testing is performed to check the strength or durability of tablets. Tablets must be strong enough to resist breakage during transportation, coating & blistering process. Friability test is performed for core or uncoated tablets & not performed for coated tablets. Coating polymers give strength & protection to tablets against breaking thats why the Friability Test not performed for Coated Tablets According to the guidelines, tablets should be tested for friability to ensure they do not lose more than a certain percentage of their weight after a specific number of rotations. Speed and Timer Controls: These allow precise setting of the rotation speed and test duration, ensuring consistency across tests. Modern machines may have digital displays for ease of use. Weighing Balance: A highly accurate balance is required to measure the weight of the tablets before and after the test. The Friability Test Apparatus consists of the following key components: Rotating Drum: Typically made of transparent plastic,Acrylic, with a diameter of about 283-291 mm and a depth of approx.40 mm. The drum has a curved baffle that allows tablets to roll and fall within the drum as it rotates. Rotation Speed: The drum rotates at a speed of 25 ± 1 rpm. Timer: Controls the duration of the test, usually set for 4 minutes, equivalent to 100 rotations. Sample Weight: Typically, a sample of 6.5 grams or a specified number of tablets is used. Powder coated mild steel robust Body . Analogue as well as Digital models. Maintenance and Calibration Regular maintenance and calibration of the friability test apparatus are crucial for ensuring accurate and reliable results. This includes: Routine Cleaning: Regularly clean the drum and other components to prevent contamination. Calibration: Periodically calibrate the rotation speed and timer to ensure they are within specified limits. Inspection: Regularly inspect the apparatus for any signs of wear or damage and replace parts as needed. Advantages of Friability Testers Standardized Test Method: Friability testers provide a standardized testing method that is widely accepted and used across the pharmaceutical industry. This ensures that manufacturers can compare their results with industry norms and regulatory requirements. Replicable and Reliable Results: These testers produce consistent and accurate results, allowing manufacturers to evaluate the durability of their tablets and granules under controlled conditions. Fast and Efficient Testing: The Friability Test is a relatively quick process, allowing manufacturers to evaluate the quality of their tablets and granules promptly. This enables manufacturers to identify and address potential issues in their formulation and manufacturing processes. Compliance with Regulatory Guidelines: Friability tests help manufacturers comply with regulatory requirements, ensuring that their products meet the industry’s strict safety and efficacy standards. Early Detection of Issues: The Friability Test can identify potential problems with tablet durability early in the development and manufacturing process. This allows for corrective actions to be taken before large-scale production, minimizing waste and reducing the risk of product failure. Cost-Effective: Friability testers are a relatively affordable investment for manufacturers, providing a cost-effective solution for ensuring the quality and durability of their tablets and granules. Limitations of Friability Testers Limited Scope: Friability testers primarily evaluate the tablet’s ability to withstand mechanical stress during handling and transportation. They do not provide insights into other critical aspects, such as the tablet’s disintegration, dissolution, or drug release properties. Not Suitable for All Tablet Types: Friability tests may not be suitable for all types of tablets, such as coated or enteric-coated tablets. These tablets may require alternative testing methods to properly assess their durability and performance. Limited to Specific Conditions: Friability testers assess the tablet’s durability under controlled conditions, which may not accurately reflect the tablet’s performance in real-world situations. Research and Development Applications Formulation Development: In R&D, friability testers are used not just for quality control but also in the development of new formulations. By testing various formulations, researchers can determine the optimal composition that balances tablet hardness with friability. Material Characterization: Friability tests can also help characterize the mechanical properties of new excipients and binders used in tablet formulations. Conclusion The friability test apparatus is an essential tool in the pharmaceutical / Food /Nutraceutical industry for ensuring tablet durability. By adhering to regulatory standards and maintaining precise machine settings and process parameters, manufacturers can ensure their products meet quality and safety standards. Regular maintenance and calibration further enhance the reliability of the test, contributing to the overall quality assurance process in tablet manufacturing.
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-11 FRIABILITY TEST APPARATUS SINGLE

ANALGESIOMETER
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-19 ANALGESIOMETER

NPH-28 DISSOLUTION RATE TEST APPARATUS Dissolution Tests are conducted to determine the drug release patterns, physiological availability and bioavailability of formulated drug products i.e for the determination of active drug ingredient in any pharmaceutical formulation – tablet or capsule. Dissolution apparatus are used throughout the product development life cycle, from Product release to stability testing and study of the product data from product to product. Then after passing or approval from the Quality control and Quality assurance, drugs are sent to markets. Dissolution test apparatus working principle: The dissolution test apparatus checks how fast a drug dissolves in your body. A tablet or capsule  is put in a container that has a medium that is prepared and operated just like the stomach or intestines functions (physiochemical conditions of the body). The container spins or moves around, and samples are taken to see how much of the medicine has dissolved over time. This helps to know how that drug works in a body. It also ensures the quality and efficacy of a product. The high head dissolution testing apparatus can be configured for1,2,3, 6 or 8 vessel configuration. Easy to operate, Accurate with Digital Timers and Digital RPM Controls. Easy to clean the bath with bottom drainage. Used in Analytical and Pharmaceutical industries. Apparatus Powder coated Mild steel body with front panel controls and a constant temperature water bath made of transparent acrylic. The round bottom glass jar of capacity 1000 ml are placed inside the bath. The jar are with  acrylic lid which allow passing of stirring shaft. The shaft is suspended from the top and is operated by the motor. The motor is electronically controlled to give speed precisely within ±1 RPM. The RPM is controlled digitally and is indicated on a digital display. Temperature is controlled by a fully solid state controller within ± 0.5°C. which maintains temperature at 37 Deg C with + 0.5 Deg C variations or Digital temperature controller. The basket assemblies and stirring paddles are of  stainlesssteel.Power required is 230 V ± 10% AC, 50 Hz
Add to wishlist
Quick View

Pharmacy Apparatus

NPH- 28 DISSOLUTION RATE TEST EQUIPMENT

NPH-12 FRIABILITY TEST APPARATUS DOUBLE DIGITAL PVG’s Digital Friability Test Apparatus is a precision Electrical  instrument used for measuring obression strength of tablets. PVG’s Friability Test Apparatus is Microprocessor based instrument designed to monitorthe resistance of tablets to stresses and to decide their suitability for the further process.These tests are carried out by quality control and R & D departments in pharmaceutical Industries. Multi-Drum Apparatus: High-throughput laboratories may use friability test apparatus with multiple drums, enabling simultaneous testing of multiple samples. This improves efficiency and ensures consistency across batches. Energy Efficiency: Advances in technology with Double Drum,Digital models have led to more energy-efficient friability tester, from PVG INTERNATIONAL which consume less power while maintaining high precision and reliability. Drum: The rotating drums, often made of plexiglass The unit is equipped with two transparent acrylic drums which rotate at a speed of 25 ± 1 RPM. Each of the two acrylic drums are provided with an arm which carries the tablets along with it up to a predetermined height and allows them to fall from that specified height, while the drums are rotating, It is fitted with a digital revolution counter showing the current number of revolutions for the test. A thumb wheel switch is used to set the desired number of rotations. Provision is made to remove the lid of the acrylic drum by unscrewing just one knob. Salient Features Programmable Timer,3 Digit Red ,Seven segment LED display Sturdy motor to drive drums at constant speed Accurate Reliable results with this low cost machine Long life Instrument with all Spares also available. Operating Temperature 10 to 50 Degree Centigrade Power required is 220 V 50 Hz A.C mains.
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-12 FRIABILITY TEST APPARATUS DOUBLE

NPH-08 ball mill motor driven It works on the principle of impact and attrition. Impact occurs when the balls are lifted by the rotating mill and then drop onto the material to be ground. The force of the impact breaks the material into smaller pieces. Attrition occurs when the balls rub against each other and against the material to be ground. Ball mills are commonly used for crushing and grinding the materials into an extremely fine form. The ball mill contains a hollow cylindrical shell that rotates about its axis. Robust, strong construction,For mixing & grinding, electrically operated. Instrument Powder coated with Heavy stable base,Fitted with Fractional Horse Power Motor Gear. With  Stainless steel jar.Capacity one kg and two Kg. Jar is interchangeable and easily removable and is light in weight . Compact unit to operate on 220 volts, 50 Hz A.C mains.
Add to wishlist
Quick View

Pharmacy Apparatus

NPH-08 TELE THERMOMETER

  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog

Address Details

PVG International
# 6 - C, New Ram Nagar, Ambala Cantt - 133 001, Haryana, India.
# P.O. Box-113

Our Visitor

001022

Contact Details

  • info@pvginternationals.com
  • info@narayanienterprises.com
  • +91-9466446612
  • +91-9728497962
  • Phone: +91-171-2651006, 2653272
  • Fax: +91-171-2653259
Copyright 2025 © PVG INTERNATIONAL
  • Home
  • About Us
  • Certifications
  • Products
  • Contact
  • Blog
  • Login
    • Mobile: +91-9466446612 +91-9728497962
    • E-Mail: info@pvginternationals.com info@narayanienterprises.com

Login

captcha

Lost your password?

Register

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

captcha